Options¶
Following is the list of options for WingFFD
module. Options are divided
into two categories: mandatory and optional.
Mandatory arguments¶
solverOptions (dict)
options for the flow solver, either adflow or dafoam
gridFile (str)
filename containing volume mesh of the wing in cgns format
ffdFile (str)
filename containing coordinates of the ffd points in plot3d format
liftIndex (int)
an int describing lift direction. Only two possible values: when the value is 2, lift direction is y. When the value is 3, lift direction is z
aeroProblem
aero-problem from baseclasses package defining information related aerodynamic analysis
Optional arguments¶
solver (str, default="adflow")
name of the solver, only two values are possible: “adflow” or “dafoam”
openfoamDir (str, default=".")
name of the directory containing supporting openfoam folders such as 0, constant, and system. The default value is the current directory
directory (str, default="output")
name of the directory where the results will saved
noOfProcessors (int, default=4)
desired number of processors to run the analysis on
sliceLocation (list, default=[])
a list containing spanwise locations where the slice is required, only works with adflow
writeDeformedFFD (bool, default=False)
option to specify whether to write deformed FFD file or not
getSurfaceForces (bool, default=False)
option to specify whether to get force at each surface mesh coordinate or not
alpha (str, default="explicit")
option to specify whether to consider alpha as an explicit or implicit variable. There are only two possbile values:
explicit
(normal analysis) andimplicit
(internal root finder). When this option is set to implicit, then for each sample secant method is used to find alpha such that target CL is achived. So, this option also takes longer to evaluate. Note: When this option is set to implicit, thenalpha
cannot be added as a DV. This option is only for adflowtargetCL (float, default=0.824)
this option only applies when
alpha
is set toimplicit
. This option specifies the value of target CL to be met. This option is only for adflowtargetCLTol (float, default=1e-4)
this option only applies when
alpha
is set toimplicit
. This option specifies the required tolerance to be met for target CL. This option is only for adflow.startingAlpha (float, default=2.5)
this option only applies when
alpha
is set toimplicit
. This option specifies the initial guess for angle of attack (in degrees) for secant method. Note that this value has a huge impact on the convergence speed of the secant method. So, it is recommended to set this value close to the expected value. This option is only for adflowsamplingCriterion (str, default="cm")
this option decides which method to use to generate Latin Hypercube samples. Only four options are available: